CHE301 — Analytical Chemistry & Instrumentation | VU Solved MCQs

Virtual Ustaad Verified VU Resource Report a wrong answer

 

CHE301 Analytical Chemistry & Instrumentation — VU solved MCQs

CHE301 Analytical Chemistry & Instrumentation covers Introduction to analytical chemistry; qualitative vs quantitative analysis, Errors; accuracy and precision, Types of errors, Volumetric (titrimetric) analysis, Primary standards, Gravimetric analysis, Complexometric titrations; EDTA, Complexometric titrations; metal-ion indicators, Oxidation–reduction titrations, Calculations used in analytical chemistry; pH, UV/Visible spectrophotometry; Beer–Lambert law, Atomic absorption spectrophotometry, Flame photometry, Infrared spectroscopy. This solved post gives you 30 verified items for Virtual University of Pakistan, 10 Midterm MCQs from Lectures 1-22, 10 Finalterm MCQs from Lectures 23-45, and 5 Midterm plus 5 Finalterm subjective questions, each with its correct answer and handout reference. Practice every question instantly in the quiz for this course. Take the CHE301 quiz

1. Midterm Solved MCQs

Q1. The branch of analytical chemistry that deals with "how much" of a substance is present in a sample is:
A) Qualitative analysis
B) Quantitative analysis
C) Instrumental analysis
D) Structural analysis
Correct answer: B — Quantitative analysis
Reference: VU handout, Lectures 1–22 — Introduction to analytical chemistry; qualitative vs quantitative analysis.
Status: Verified

Q2. Accuracy is defined as:
A) The reproducibility of repeated measurements
B) The closeness of a measured value to the true value
C) The smallest difference a measurement can detect
D) The range over which a method works
Correct answer: B — The closeness of a measured value to the true value
Reference: VU handout, Lectures 1–22 — Errors; accuracy and precision.
Status: Verified

Q3. An error that is caused by a faulty instrument calibration and affects every measurement in the same direction is a:
A) Random error
B) Systematic (determinate) error
C) Gross error
D) Sampling error
Correct answer: B — Systematic (determinate) error
Reference: VU handout, Lectures 1–22 — Types of errors.
Status: Verified

Q4. The point in a titration at which the indicator changes colour is called the:
A) Equivalence point
B) End point
C) Neutralisation point
D) Saturation point
Correct answer: B — End point
Reference: VU handout, Lectures 1–22 — Volumetric (titrimetric) analysis.
Status: Verified

Q5. Which of the following is a requirement for a primary standard?
A) It must be hygroscopic
B) It must be available in high purity and be stable in air
C) It must have a very low molar mass
D) It must react slowly with the analyte
Correct answer: B — It must be available in high purity and be stable in air
Reference: VU handout, Lectures 1–22 — Primary standards.
Status: Verified

Q6. In gravimetric analysis, the precipitate formed must be:
A) Soluble and of unknown composition
B) Pure, insoluble and of definite known composition
C) Colloidal and easily oxidised
D) Volatile at room temperature
Correct answer: B — Pure, insoluble and of definite known composition
Reference: VU handout, Lectures 1–22 — Gravimetric analysis.
Status: Verified

Q7. EDTA titrations are used for the determination of:
A) Acids only
B) Metal ions
C) Halide ions only
D) Organic solvents
Correct answer: B — Metal ions
Reference: VU handout, Lectures 1–22 — Complexometric titrations; EDTA.
Status: Verified

Q8. Eriochrome Black T is used as an indicator in EDTA titrations. At the end point its colour changes from:
A) Blue to wine red
B) Wine red to blue
C) Colourless to pink
D) Yellow to orange
Correct answer: B — Wine red to blue
Reference: VU handout, Lectures 1–22 — Complexometric titrations; metal-ion indicators.
Status: Verified

Q9. Potassium permanganate (KMnO₄) in redox titrations acts as:
A) A reducing agent only
B) An oxidising agent and its own indicator
C) A buffer solution
D) A complexing agent
Correct answer: B — An oxidising agent and its own indicator
Reference: VU handout, Lectures 1–22 — Oxidation–reduction titrations.
Status: Verified

Q10. A solution has a hydrogen-ion concentration of 1.0 × 10⁻³ mol/L. Its pH is:
A) 1
B) 3
C) 7
D) 10
Correct answer: B — 3
Reference: VU handout, Lectures 1–22 — Calculations used in analytical chemistry; pH.
Status: Verified

2. Finalterm Solved MCQs

Q1. The Beer–Lambert law is expressed as:
A) A = εbc
B) A = ε/bc
C) T = εbc
D) A = bc/ε
Correct answer: A — A = εbc
Reference: VU handout, Lectures 23–45 — UV/Visible spectrophotometry; Beer–Lambert law.
Status: Verified

Q2. The visible region of the electromagnetic spectrum lies approximately between:
A) 200–400 nm
B) 400–700 nm
C) 700–1000 nm
D) 10–200 nm
Correct answer: B — 400–700 nm
Reference: VU handout, Lectures 23–45 — UV/Visible spectrophotometry.
Status: Verified

Q3. In atomic absorption spectroscopy (AAS), the light source most commonly used is the:
A) Tungsten lamp
B) Deuterium lamp
C) Hollow cathode lamp
D) Xenon arc lamp
Correct answer: C — Hollow cathode lamp
Reference: VU handout, Lectures 23–45 — Atomic absorption spectrophotometry.
Status: Verified

Q4. Flame photometry is most commonly used for the determination of:
A) Iron and copper
B) Sodium and potassium
C) Lead and cadmium
D) Calcium and magnesium only
Correct answer: B — Sodium and potassium
Reference: VU handout, Lectures 23–45 — Flame photometry.
Status: Verified

Q5. Infrared (IR) spectroscopy is mainly used to identify:
A) The molecular weight of a compound
B) The functional groups present in a molecule
C) The concentration of metal ions
D) The crystal structure of a solid
Correct answer: B — The functional groups present in a molecule
Reference: VU handout, Lectures 23–45 — Infrared spectroscopy.
Status: Verified

Q6. In chromatography, the retention factor (Rf) is defined as:
A) Distance moved by the solvent front ÷ distance moved by the solute
B) Distance moved by the solute ÷ distance moved by the solvent front
C) Distance moved by the solute × distance moved by the solvent front
D) Time taken by the solute ÷ time taken by the solvent
Correct answer: B — Distance moved by the solute ÷ distance moved by the solvent front
Reference: VU handout, Lectures 23–45 — Chromatography; paper and thin-layer chromatography.
Status: Verified

Q7. Which of the following is used as a carrier gas in gas chromatography?
A) Oxygen
B) Chlorine
C) Helium
D) Carbon dioxide
Correct answer: C — Helium
Reference: VU handout, Lectures 23–45 — Gas chromatography.
Status: Verified

Q8. A pH meter measures pH using a:
A) Calomel electrode only
B) Glass electrode sensitive to hydrogen ions
C) Platinum electrode
D) Silver–silver chloride electrode only
Correct answer: B — Glass electrode sensitive to hydrogen ions
Reference: VU handout, Lectures 23–45 — Electroanalytical methods; potentiometry.
Status: Verified

Q9. In mass spectrometry, ions are separated on the basis of their:
A) Mass only
B) Charge only
C) Mass-to-charge ratio (m/z)
D) Atomic number
Correct answer: C — Mass-to-charge ratio (m/z)
Reference: VU handout, Lectures 23–45 — Mass spectrometry.
Status: Verified

Q10. Fluorescence differs from absorption in that the emitted radiation has:
A) A shorter wavelength than the absorbed radiation
B) A longer wavelength than the absorbed radiation
C) The same wavelength as the absorbed radiation
D) No relation to the absorbed radiation
Correct answer: B — A longer wavelength than the absorbed radiation
Reference: VU handout, Lectures 23–45 — Molecular luminescence; fluorescence.
Status: Verified

3. Midterm Subjective

Q1. Distinguish between accuracy and precision. Give one example showing a result can be precise but not accurate.
Answer: Accuracy is the closeness of a measured value to the true (accepted) value; precision is the agreement (reproducibility) among repeated measurements of the same quantity. A result can be precise but not accurate when all replicates agree closely with each other but are all far from the true value — for example, four titrations giving 10.45, 10.46, 10.44 and 10.45 mL (very precise) when the true titre is 10.00 mL (inaccurate, e.g. because the burette was miscalibrated). Such a bias is a systematic error: it affects accuracy but not precision. Random errors, by contrast, scatter results and reduce precision.
Reference: VU handout, Lectures 1–22 — Errors; accuracy and precision.
Status: Verified

Q2. What are systematic and random errors? How can each be reduced or detected?
Answer: Systematic (determinate) errors have a definite, identifiable cause and bias every measurement in the same direction — e.g. a miscalibrated balance, an impure primary standard, or a faulty indicator. They affect accuracy and are detected by analysing a standard reference material, running blank determinations, or using a different method; they are reduced by calibrating instruments, using pure reagents and correcting for the blank. Random (indeterminate) errors arise from unpredictable small variations (e.g. reading a burette, temperature fluctuations) and scatter results on both sides of the mean. They affect precision and cannot be eliminated, but their effect is reduced by taking more replicate measurements and reporting the mean, and they are quantified by the standard deviation.
Reference: VU handout, Lectures 1–22 — Types of errors.
Status: Verified

Q3. Describe the steps of a gravimetric analysis.
Answer: (1) Weigh the sample accurately. (2) Dissolve it and treat it so the analyte is in a suitable form. (3) Precipitate the analyte with a reagent that gives a pure, insoluble precipitate of known composition (precipitation). (4) Digest the precipitate (warm it in the mother liquor) so the particles grow and impurities are reduced. (5) Filter the precipitate and wash it free of soluble impurities. (6) Dry or ignite it to a constant weight at a temperature that gives a compound of definite composition. (7) Weigh the precipitate and calculate the analyte from the gravimetric factor (mass of analyte per unit mass of precipitate). Example: sulphate is precipitated as BaSO₄ and weighed to find sulphur.
Reference: VU handout, Lectures 1–22 — Gravimetric analysis.
Status: Verified

Q4. What is a primary standard? State its requirements and give two examples.
Answer: A primary standard is a highly pure, stable compound that can be weighed accurately and used to prepare a solution of exactly known concentration (a standard solution), or to standardise another solution. Requirements: (1) very high purity (typically > 99.9%); (2) stable in air — not hygroscopic, not oxidised by air, not volatile; (3) readily soluble; (4) high molar mass, so weighing errors are small; (5) reacts rapidly and stoichiometrically with the analyte. Examples: anhydrous sodium carbonate (Na₂CO₃) for standardising acids, and potassium hydrogen phthalate (KHP) for standardising bases; potassium dichromate (K₂Cr₂O₇) is a primary standard for redox titrations.
Reference: VU handout, Lectures 1–22 — Primary standards; standard solutions.
Status: Verified

Q5. Five replicate determinations of chloride in a sample gave 10.2, 10.4, 10.3, 10.5 and 10.3 mg/L. Calculate the mean and the standard deviation.
Answer: Mean = (10.2 + 10.4 + 10.3 + 10.5 + 10.3)/5 = 51.7/5 = 10.34 mg/L. Deviations from the mean: −0.14, +0.06, −0.04, +0.16, −0.04. Squared deviations: 0.0196 + 0.0036 + 0.0016 + 0.0256 + 0.0016 = 0.052. Sample variance s² = 0.052/(n − 1) = 0.052/4 = 0.013. Standard deviation s = √0.013 ≈ 0.11 mg/L. So the result is 10.34 ± 0.11 mg/L. The standard deviation measures the precision (scatter) of the replicates.
Reference: VU handout, Lectures 1–22 — Statistical treatment of data; mean and standard deviation.
Status: Verified

4. Finalterm Subjective

Q1. State the Beer–Lambert law and use it to calculate the concentration of a solution whose absorbance is 0.600 in a 1 cm cell, given ε = 1.2 × 10⁴ L mol⁻¹ cm⁻¹.
Answer: The Beer–Lambert law states that the absorbance A of a solution is directly proportional to the concentration c of the absorbing species and to the path length b of the cell: A = εbc, where ε is the molar absorptivity (a constant for the substance at a given wavelength). Absorbance is also A = −log T, where T is the transmittance. Calculation: c = A/(εb) = 0.600/(1.2 × 10⁴ × 1) = 5.0 × 10⁻⁵ mol/L. The law holds for dilute solutions and monochromatic radiation; deviations occur at high concentrations, in the presence of stray light, or when the absorbing species associates or dissociates.
Reference: VU handout, Lectures 23–45 — UV/Visible spectrophotometry; Beer–Lambert law.
Status: Verified

Q2. Explain the principle of atomic absorption spectroscopy (AAS) and name its main components.
Answer: In AAS the sample is atomised (usually in a flame or a graphite furnace) to produce free ground-state atoms. Radiation of a characteristic wavelength from a hollow cathode lamp (made of the element being determined) is passed through the atom cloud; the atoms absorb at their resonance lines, and the decrease in intensity is measured. The absorbance is proportional to the concentration of the element (Beer–Lambert law), so the method is used for trace-metal analysis (e.g. mineral analysis of plant tissues in the CHE301 lab). Main components: (1) radiation source — hollow cathode lamp; (2) atomiser — flame (air–acetylene) or graphite furnace; (3) monochromator — selects the resonance line; (4) detector — photomultiplier tube; (5) readout/amplifier system.
Reference: VU handout, Lectures 23–45 — Atomic absorption spectrophotometry.
Status: Verified

Q3. What is the difference between UV-Visible and infrared (IR) spectroscopy? What information does each give?
Answer: UV-Visible spectroscopy (200–800 nm) involves electronic transitions: absorption of UV or visible light promotes electrons from bonding or non-bonding orbitals to anti-bonding orbitals (π→π*, n→π*). It is mainly quantitative (Beer–Lambert law) and identifies conjugated systems and chromophores; a UV-Vis spectrum has broad bands and gives the wavelength of maximum absorption (λmax) and the molar absorptivity. IR spectroscopy (4000–400 cm⁻¹) involves molecular vibrations (stretching and bending of bonds). It is mainly qualitative: the positions of absorption bands identify the functional groups present (e.g. C=O stretch near 1700 cm⁻¹, O–H stretch near 3400 cm⁻¹), so an IR spectrum is a "fingerprint" of the molecule. In short: UV-Vis tells how much of a chromophore is present; IR tells which functional groups are present.
Reference: VU handout, Lectures 23–45 — UV/Visible and infrared spectroscopy.
Status: Verified

Q4. Compare paper chromatography and thin-layer chromatography (TLC). How is the Rf value calculated and used?
Answer: Both are planar liquid chromatography techniques in which the components of a mixture separate as a solvent (mobile phase) moves through a stationary phase. In paper chromatography the stationary phase is water held in the fibres of a filter paper and the mobile phase is an organic solvent; it is cheap but slow and gives diffuse spots. In TLC the stationary phase is a thin layer of adsorbent (silica gel or alumina) coated on a glass or aluminium plate; separation is by adsorption, it is faster, gives sharper spots, and the plate can be heated or sprayed with reagents to visualise colourless compounds (used in the CHE301 lab for separating biomolecules). In both, the retention factor Rf = (distance moved by the solute from the origin) ÷ (distance moved by the solvent front from the origin). Rf is always between 0 and 1 and is characteristic of a compound in a given solvent system, so an unknown is identified by comparing its Rf with that of a known standard run on the same plate.
Reference: VU handout, Lectures 23–45 — Chromatography; paper and thin-layer chromatography.
Status: Verified

Q5. How does a glass electrode measure pH? State the Nernstian slope at 25 °C.
Answer: The glass electrode is an ion-selective electrode whose thin glass membrane develops a potential that depends on the hydrogen-ion activity of the solution in contact with it. The membrane potential follows the Nernst equation: E = E° − (2.303 RT/F) × pH, so the measured potential changes linearly with pH. At 25 °C the slope (2.303 RT/F) is 59.16 mV per pH unit — a change of one pH unit changes the electrode potential by about 59 mV. In practice the glass electrode is paired with a reference electrode (e.g. calomel or Ag/AgCl) and the pH meter is calibrated with standard buffer solutions (e.g. pH 4, 7 and 10) before measurement. The method is potentiometric: it measures a potential at (nearly) zero current.
Reference: VU handout, Lectures 23–45 — Electroanalytical methods; potentiometry and pH measurement.
Status: Verified

Frequently asked questions

Is the Midterm from Lectures 1-22?

Yes — Midterm covers Lectures 1-22 and Finalterm covers Lectures 23-45.

Does the quiz work from this post?

Yes — use the 'Take the CHE301 quiz' link above; the quiz is already live for this course.

Are the answers verified?

Yes — all 30 items are marked Verified, solved independently and cross-checked against at least two independent sources.